1 适用范围
1.1 本标准适用于固定污染源有组织排放和无组织排放的jia醇测定。
1.2 以3倍噪音色谱峰高值计算,当色谱进样量为1.0 ml时,方法的检出限为2 mg/m3;定量测定的浓度范围为5.0-104 mg/m3。
2 方法原理
载气携带含有jia醇(CH3OH)的试样通过装有固定相的色谱柱,流出色谱柱的甲chun由氢火焰离子化检测器(FID)测定。以标准样品色谱峰的保留时间进行定性,以峰高(或峰面积)定量。
3 引用标准
下列标准所包含的条文,通过在本标准中引用而构成为本标准的条文。
GB 16297-1996 大气污染物综合排放标准
GB 16157-1996 固定污染源排气中颗粒物测定和气态污染物采样方法
4 试剂和材料
4.1 色谱固定液:5%聚乙二醇(Carbowax 20M)。
4.2 载体:石墨碳黑(Carbopack B) 80~120目。
4.3 载气:体积分数为高纯氮99.99%。
4.4 燃烧气:体积分数为纯氢99.9%。
4.5 助燃气:空气。
4.6 无碱玻璃棉。
名称:填充柱
固定液:5% 聚乙二醇(Carbowax20M)
载体:石墨化碳黑(Carbopack B)80-120目
规格:2m*3mm
材质:不锈钢(玻璃)
应用:HJ/T 33-1999 固定污染源排气中甲chun的测定 气相色谱法



1 Scope of application
1.1 This standard is applicable to the determination of organic and unorganized emissions from fixed pollution sources.
1.2 Calculated by 3 times the noise chromatographic peak height value, when the chromatographic injection volume is 1.0 ml, the detection limit of the method is 2 mg/m3; the concentration range for quantitative determination is 5.0-104 mg/m3.
2 Principles of the method
The carrier gas carries a sample containing jia alcohol (CH3OH) through a chromatographic column equipped with a stationary phase, and the methanol flowing out of the chromatographic column is measured by a hydrogen flame ionization detector (FID). Qualitatively based on the retention time of the chromatographic peak of the standard sample, and quantitatively based on the peak height (or peak area).
3 Reference standards
The provisions contained in the following standards constitute the provisions of this standard through quotation in this standard.
GB 16297-1996 Comprehensive Emission Standard of Air Pollutants
GB 16157-1996 Determination of particulate matter in exhaust gas from stationary sources and sampling method for gaseous pollutants
4 Reagents and materials
4.1 Chromatographic stationary liquid: 5% polyethylene glycol (Carbowax 20M).
4.2 Carrier: Graphite carbon black (Carbopack B) 80~120 mesh.
4.3 Carrier gas: the volume fraction is 99.99% of high purity nitrogen.
4.4 Combustion gas: the volume fraction of pure hydrogen is 99.9%.
4.5 Combustion gas: air.
4.6 Alkali-free glass wool.
Name: Packed column
Fixative: 5% polyethylene glycol (Carbowax20M)
Carrier: Graphitized carbon black (Carbopack B) 80-120 mesh
Specification: 2m*3mm
Material: stainless steel (glass)
Application: HJ/T 33-1999 Determination of Achun in Exhaust Gas from Stationary Pollution Sources Gas Chromatography
-